Maintenance Object Repair Procedures
555-233-123
10-1858 Issue 4 May 2002
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is highly destructive and can only be
initiated by a system technician-demanded reset board UUCSS command.
Table 10-671. TEST #53 SAKI Sanity Test
Error
Code
Te s t
Result Description/Recommendation
None ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a
maximum of 5 times.
1005 ABORT Wrong circuit pack configuration to run this test. This error
applies only to DS1 Interface circuit packs. It means the DS1
Interface circuit pack is providing timing for the system, and
therefore, it cannot be reset without major system disruptions.
1. If the circuit pack needs to be reset, then set
synchronization to another DS1 Interface circuit pack or to
the Tone-Clock circuit pack and try again. Refer to
‘‘SYNC
(Synchronization)’’
Maintenance documentation.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute the reset board command again.
2100 ABORT System resources required for this test are not available.
1. Retry the reset board command at 1-minute intervals a
maximum of 5 times.
1 FAIL The circuit pack failed to reset.
Continued on next page