UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1867 555-233-123
1300 FAIL The CSU Module/T1 Sync Splitter or the E1 Sync Splitter is
missing.
The CSU Module/T1 Sync Splitter is missing: The Near-End
CSU Type
field on the add ds1 form has been administered as
integrated but the 120A1 CSU Module or the 401A T1 Sync
Splitter is not physically connected to the UDS1 board on the back
of the port carrier.
1. If using the 120A1 CSU Module or the 401A T1 Sync Splitter,
plug the CSU Module/T1 Sync Splitter into the UDS1 circuit
pack’s connector on the I/O connector panel on back of the
carrier. Otherwise, change the
Near-End CSU Type field
using the change ds1 form to
other.
2. Run the test again.
The E1 Sync Splitter is missing: The
E1 Sync-Splitter?
field on the add ds1 form has been administered as y but the
402A or 403A E1 Sync Splitter is not physically connected to the
UDS1 board on the back of the port carrier.
1. If using the 402A or 403A E1 Synchronization Splitter, plug
the E1SS into the UDS1 circuit pack’s connector on the I/O
connector panel on back of the carrier. Otherwise, change the
E1 Sync-Splitter? field using the change ds1 form to
n.
2. Run the test again.
Table 10-673. TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page