Maintenance Object Repair Procedures
555-233-123
10-1884 Issue 4 May 2002
Table 10-676. TEST #141 Yellow Alarm Inquiry Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000 ABORT Response to the test was not received within the allowable time
period. This may be due to hyperactivity. Error Type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is out
of service and one or more of the following symptoms may be
exhibited.
1. The UDS1-BD tests (such as Test #138 and Test #139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a no
board result.
3. A busyout or a release has no affect on the test results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from
the system, and all of the trunks for this circuit pack are
placed into the out of service state. The system will try to
restore the circuit pack within 15 minutes. When no faults
are detected for 15 minutes, the UDS1 interface circuit pack
is restored to normal operation. All of the trunks for the
UDS1 interface circuit pack are then returned to the in
service state. Hyperactivity is often caused by the
associated facility. In such a case, faults (such as slips,
misframes, or blue alarms) would be entered in the error
log. In addition, many hardware errors would be logged
against the associated trunk circuits. If the facility is OK and
the error occurs again after 15 minutes, replace the circuit
pack.
Continued on next page