UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1901 555-233-123
1 to 17
(cont.)
FAIL
(cont’d.)
If the UDS1 connects to a line-side terminating device such as a
PRI terminal adapter:
1. Retry the command at 1-minute intervals for a maximum of 5
times.
2. Enter the list measurement ds1-log UUCSS command to
read the error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating
device are administered using the same signaling mode,
framing mode, and line coding.
4. Investigate the maintenance status of the line-side
terminating device. Refer to the ’Line-Side Terminating
Device Operating Manual’ for information.
5. Contact the vendor of the line-side terminating device to
diagnose the equipment.
6. Check the physical connection of the UDS1 interface circuit
pack to the terminating device, and check the premise
distribution system (or the intra-premise wiring) for physical
connection failures.
7. Replace the local UDS1 interface circuit pack and repeat the
test.
Table 10-680. TEST #145 Misframe Alarm Inquiry Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page