Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-20 Issue 4 May 2002
Output
The following example is a display of the busyout station command.
Field descriptions
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
Type of busied out maintenance object
Alt. Name
Extension
Result
Test result: Pass, Fail, Abort
Error Code
Numeric code explaining why the release failed or aborted. Refer to
the detailed list of codes by test number for each MO.
busyout station 1002 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1102 DIG-LINE PASS
Command successfully completed