UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1927 555-233-123
2000 ABORT Response to the test was not received within the allowable time
period. This may be due to hyperactivity. Error Type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is
out of service and one or more of the following symptoms may
be exhibited.
1. The UDS1-BD tests (such as Test #138 and Test #139) are
aborting with error code 2000.
2. The tests run on the ports of this circuit pack are returning a
no board result.
3. A busyout or a release has no affect on the test results.
4. A list config command shows that the circuit pack and the
ports are properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated
from the system, and all of the trunks for this circuit pack
are placed into the out of service state. The system will try
to restore the circuit pack within 15 minutes. When no
faults are detected for 15 minutes, the UDS1 interface
circuit pack is restored to normal operation. All of the
trunks for the UDS1 interface circuit pack are then
returned to the in service state. Hyperactivity is often
caused by the associated facility. In such a case, faults
(such as slips, misframes, or blue alarms) would be
entered in the error log. In addition, many hardware errors
would be logged against the associated trunk circuits. If
the facility is OK and the error occurs again after 15
minutes, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
Table 10-687. TEST #1214 One-Way Span Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page