Maintenance Object Repair Procedures
555-233-123
10-1932 Issue 4 May 2002
The list measurements ds1 summary command will display the length of time
the test ran (Test Duration field) and number of bit errors detected
(Loopback/Span Test Bit-Error Count field).
To restore the trunks or ports on the UDS1 Interface circuit pack to the in-service
state, execute release board.
Table 10-689. TEST #1216 End Loopback/Span Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Internal system error
1. Retry the test ds1-loop UUCSS end-loopback/span-test
command at 1-minute intervals a maximum of 5 times.
1005 ABORT End Loopback/Span Test cannot be executed in the current
configuration. To run this test, the TN464F or later suffix DS1
board must be administered for 24-channel operation. The “Bit
Rate” field on the DS1 circuit pack administration form must be
set to “1.544” for 24-channel operation.
1015 ABORT Ports on the UDS1 Interface circuit pack have not been busied
out to out-of-service.
1. Enter the busyout board UUCSS command to put all trunks
or ports of the UDS1 Interface circuit pack into the
out-of-service state.
2. Retry the command.
Continued on next page