UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1935 555-233-123
This test is only be executed on TN464F or later suffix UDS1 circuit packs
administered for 24-channel operation (1.544 bit rate).
If the 120A1 CSU Module or the 401A T1 Sync Splitter is not physically installed,
the status LEDs are always off and this test aborts.
Table 10-690. TEST #1227 ICSU Status LEDs Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1005 ABORT The ICSU Status LEDs test can not be executed for the current
configuration. The test applies only to TN464F or later UDS1
circuit packs administered for 24-channel operation (1.544 bit
rate).
1. If the circuit pack is a TN464F or later suffix UDS1 circuit
pack, then retry the command.
1951 ABORT The ICSU Status LEDs Test can not be executed because a
120A1 or later suffix CSU Module or a 401A or later suffix T1
Sync Splitter is not physically installed. If using a 120A1 CSU
Module or the 401A T1 Sync Splitter, physically connect it to the
UDS1-BD board on the back of the port carrier. Otherwise,
ignore this abort.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
2500 ABORT Internal system error.
1. Retry the command.
Continued on next page