Maintenance Object Repair Procedures
555-233-123
10-1942 Issue 4 May 2002
Notes:
a. Error Type 1: Circuit pack stopped functioning or is not physically present.
1. Verify that the circuit pack is present.
2. If circuit pack is present, reset the circuit pack (reset board
UUCSS).
3. If the error persists, replace the circuit pack.
b. Error Type 18: The VAL circuit pack is busied out.
c. Error Type 217: applies to 10 circuit packs:
1. Remove the circuit pack(s) against which the error is logged.
d. Error Type 257: Transient communication problem between switch and
circuit pack; does not affect service and can be ignored.
1. Ignore this error, unless the Control Channel Loop Test (#52) fails.
2. If Test #52 fails, replace the circuit pack.
Repetitive failures of the Control Channel Loop Test indicate circuit pack
hardware failure.
e. Error Type 513: Circuit pack detected and reported hardware failure.
1. Reset the circuit pack (reset board UUCSS).
Aux Data:
3845 (v) Any
3846 (w) Any
3848 (x) Any
3851 (y) Any
3852 (z) Any
3853 (aa) Any
3854 (ab) Any
3855 (ac) Any
3856 (ad) Any
4352 External RAM error
4353 Internal RAM error
Table 10-692. VAL-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page