Maintenance Object Repair Procedures
555-233-123
10-1946 Issue 4 May 2002
1. Busyout (busyout board UUCSS) and release (release board
UUCSS) the circuit pack.
2. Allow 30 minutes for condition to clear itself.
3. To re-establish circuit pack into service manually, busyout (busyout
board UUCSS), reset (reset board UUCSS), and release (release
board UUCSS) the circuit pack.
4. If error recurs within 15 minutes, replace the circuit pack.
5. If the same error occurs on a different circuit pack, follow normal
escalation procedures.
r. Error Type 3840: Circuit pack received bad control channel message from
switch.
Aux Data:
If Error Type 3999:
And traffic
volume is: Then:
Does not accompany
Error Type 3586,
Heavy Circuit pack is in service, but sent
at least half hyperactive
threshold. With heavy traffic, this
is normal.
Does not accompany
Error Type 3586,
Light Circuit pack is in service, but sent
at least half hyperactive
threshold. With light traffic, this
error indicates a problem with the
circuit pack, its links, or the
equipment attached to the links.
Accompanies Error
Type 3586,
Either Light or
Heavy
Switch removed hyperactive
circuit pack.
4096 Bad major heading
4097 Bad port number
4098 Bad data
4099 Bad sub-qualifier
4100 State inconsistency
4101 Bad logical link
4102 Bad application identifier