VAL-PT (Voice Announcements over LAN Packet/Port)
Issue 4 May 2002
10-1965 555-233-123
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Looparound Test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures.
b. Error Type 257: VAL port detected overrun or underrun condition that can
indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
c. Error Type 3585: TDM Port Looparound Test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. Refer to TDM Looparound Test (#1285) repair procedure.
Table 10-703. VAL-PT Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 There is no short test sequence for this MO. All tests are available in the Long Test Sequence.
Refer to the appropriate test description and follow the recommended procedures.
0Any Any Anytest port UUCSSpp l
1 (a) 0 SCOTCH Sync
Looparound Test
(#1275)
MINOR ON test port UUCSSpp l r 3
257 (b) 0 WARNING OFF
3585 (c) 0-1 TDM Looparound
Test (#1285)
MAJOR ON test port UUCSSpp l r 3
Continued on next page