Maintenance Object Repair Procedures
555-233-123
10-2000 Issue 4 May 2002
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the UDS1
Interface circuit pack to ensure that the wideband access endpoint port’s
translation is correct.
Table 10-719. TEST #36 Audit and Update Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal System Error.
1. Retry the command at one minute intervals a maximum of
5 times.
1006 ABORT The port is out-of-service. If the port is busied out:
1. Issue release access-endpoint <extension> command
to put the port back into in-service.
2. Retry the test command.
If the port is not busied out:
1. Check the error and alarm logs for WAE-PORT and
UDS1-BD errors and alarms. Follow the recommended
repair procedures.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at one minute intervals a maximum of
5 times.
FAIL Internal system error.
1. Retry the command at one minute intervals a maximum of
5 times.
PASS Port translation has been updated successfully.
Continued on next page