XXX-BD (Common Port Circuit Pack)
Issue 4 May 2002
10-2009 555-233-123
Table 10-721. TEST #50 NPE Audit Test
Error
Code Test Result Description/Recommendation
none or
2100
ABORT System resources required for this test are not
available.
1019 ABORT Test already in progress.
FAIL Internal System Error.
1. Retry the command at 1-minute intervals a
maximum of 5 times.
PASS The circuit pack’s NPEs have been updated with their
translation.
EXTRA BD Certain circuit packs have limitations on how many
circuit packs can be in the system or port network such
as the Maintenance/Test circuit pack (TN771B or
TN771C), the Tone Detector circuit pack (TN748B,
TN748C or TN748D) and the Call Classifier (TN744).
The Maintenance/Test circuit pack allows only one
circuit pack per port network. The Tone Detector and
Call Classifier allow only 10 circuit packs in each
system. All additional circuit packs return EXTRA-BD
and should be removed.
any NO BOARD This is normal if the test is being done when (a) the
circuit pack is not physically in the system or (b) the
system is booting up. Otherwise, there is some
inconsistency between the physical configuration and
the data kept in the system.
1. Verify that the circuit pack is physically in the
system.
2. Verify that the system is not in a stage of booting
up.
3. Retry the command at 1-minute intervals for a
maximum of 5 times.
Continued on next page