XXX-BD (Common Port Circuit Pack)
Issue 4 May 2002
10-2011 555-233-123
1008 ABORT Could not allocate a ringing circuit for one of the following
reasons: all the ringing circuits are in use; the ringing
generator is defective; ringing generator is not wired
correctly.
1. If the test continues to abort, look for RING-GEN error in
Error Log.
a. If there are RING-GEN errors, refer to RING-GEN
Maintenance documentation and try to resolve any
problem(s). Go to Step 2.
b. If there are no RING-GEN errors, and the test
continues to abort, issue the test board PCSS
command on other TN742, TN769, or TN746 Analog
circuit packs. If an ABORT with error code 1008
occurs for this test on other circuit packs as well, the
ringing generator may be defective or may not be
wired properly. Refer to RING-GEN Maintenance
documentation for details. If an ABORT with error
code 1008 does NOT occur on the other ports, then
all four ring generators are in use. Exit from this
documentation.
2. Retry the command.
Table 10-722. TEST #51 Ringing Application Circuit Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page