Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-86 Issue 4 May 2002
1914 IP RRJ-ProdID
search fail
Registration rejected because the
search for registering application’s
Product ID failed.
T/S: Product
ID of the
registering
application
Major version
number
1915 IP RRJ-Invalid
endpt/Ver
Registration rejected because the
endpoint version is not compatible
with the gatekeeper version.
IP address Major version
number in
2nd byte;
minor version
number in low
byte
1916 IP RRJ-No H323
NonStdData
Registration rejected; non-standard
data are missing in the RRQ from
authenticating application.
0 IP address
1917 IP RRJ-Invld H323
ObjID
Registration rejected; Object ID in the
RRQ is invalid.
Object ID IP address
1918 IP RRJ-Invld H225
NSData
Registration rejected; cannot decode
H225 non-standard data (NSD)
message.
0 IP address
1919 IP RRJ-Bad H225
NSDchoice
Registration rejected; unexpected
NSD message received from
registering application.
NSD choice IP address
1920 IP RRJ-TTI: new
LM fail
Registration rejected; failure in
creating new Login Manager.
Possible causes are:
■ No available heap memory to
create LoginMgr
■ Cannot start LoginMgr timer
■ Clock not set
UID IP address
1921 IP RRJ-IP-TTI port
fail
Registration rejected; failure when
inserting IP TTI port.
UID IP address
1922 IP RRJ-TTI or RO
inactive
Registration for an IP set with TTI
service rejected. Possible causes:
■ TTI is not enabled on the System
Parameters Customer Options
screen.
■ Remote Office is not enabled on
the System Parameters Feature
Options screen.
0 IP address
Table 8-2. Denied IP events — Continued
Event
Type
Event
Description Explanation
Event
Data 1
Event
Data 2
Continued on next page