display system-parameters maintenance
Issue 4 May 2002
8-113555-233-123
Output
The following display shows a typical result when display system-parameters
maintenance is entered.
display system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1000000000
First OSS Telephone Number: 5551212 Abbrev Alarm Report? y
Second OSS Telephone Number: 5551213 Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y
Restart Notification? y
Test Remote Access Port? n
CPE Alarm Activation Level: none
Packet Bus Activated? n
Customer Access to INADS Port? n
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 22
: 00 Stop Time: 04: 00
Daily Maintenance: daily Save Translation: daily
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no EXP-LINK Interchange: no
display system-parameters maintenance Page 2 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
MAINTENANCE THRESHOLDS ( Before Notification )
Minimum Threshold for TTRs: 4
Minimum Threshold for CPTRs: 1
Minimum Threshold for Call Classifier Ports: _
TERMINATING TRUNK TRANSMISSION TEST (Extension)
Test Type 100: Test Type 102: Test Type 105:
ISDN MAINTENANCE
ISDN-PRI TEST CALL Extension: _____ ISDN BRI Service SPID: _____
DS1 MAINTENANCE
DSO Loop-Around Test Call Extension: 1001
SPE OPTIONAL BOARDS
Disk? y
Packet Intf1? y Packet Intf2? n Packet Intf3? n