list measurements clan ppp
Issue 4 May 2002
8-159555-233-123
Output
The following example shows the output from list measurements clan ppp.
Field descriptions
Date
The date that the data was collected.
Time
The current 15-minute interval in which the action was performed
CRC Check
The error count for CRC errors
Total
Total value of the board counter.
The counter value can be up to 7 digits long. After the occurrence
of N/A the delta equals the total. Busyout or release of a board or
a port, (reset board) and reseating the board all clear the
firmware counters.
Delta
The difference between the current and the previous sample
Invalid Frame
The number of invalid (misaligned) frames detected.
CHAP Failures
The number of failed attempts for ppp authentication
list measurements clan ppp 1C1001 Page 1 of x
Switch Name: sierra Date:02/02/1999
C-LAN PPP PERFORMANCE MEASUREMENT DETAILED REPORT
Date Time CRC Check Invalid Frame CHAP Failures
Total Delta Total Delta Total Delta
02/01 03:08 85 25 185 85 5 0
02/01 02:53 60 60 100 100 5 5
02/01 02:38 N/A N/A N/A N/A N/A N/A
02/01 02:23 1000060 10 1000090 10 25 5
02/01 02:08 1000050 1000050 1000080 1000080 20 20