Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-166 Issue 4 May 2002
SEVERELY ERR
SECS
The value of the severely errored seconds counter for the specified
15-minute interval (0 - 900 or N/A if data for the 15-minute interval
is invalid).
FAILED
SECONDS
The value of the failed seconds counter for the specified 15-minute
interval (0 - 900 or N/A if data for the 15-minute interval is invalid).
VALID
INTERVAL
This field indicates whether the data for the specified 15-minute
interval is valid. Data is considered valid when a count for that
15-minute interval. If the field has a value of y, the data for the four
error categories is valid; otherwise, the data is invalid.
Data is considered valid when a count for that 15-minute interval is
retrieved and none of the following invalid conditions occur:
— If a system warm start or a system cold start occurred
during the interval
— If the DS1 circuit pack was not inserted during the
interval
— If the system time was changed during the interval
— If the system was too busy to respond to a poll request
for the interval.