Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-166 Issue 4 May 2002
SEVERELY ERR
SECS
The value of the severely errored seconds counter for the specified
15-minute interval (0 - 900 or N/A if data for the 15-minute interval
is invalid).
FAILED
SECONDS
The value of the failed seconds counter for the specified 15-minute
interval (0 - 900 or N/A if data for the 15-minute interval is invalid).
VALID
INTERVAL
This field indicates whether the data for the specified 15-minute
interval is valid. Data is considered valid when a count for that
15-minute interval. If the field has a value of y, the data for the four
error categories is valid; otherwise, the data is invalid.
Data is considered valid when a count for that 15-minute interval is
retrieved and none of the following invalid conditions occur:
If a system warm start or a system cold start occurred
during the interval
If the DS1 circuit pack was not inserted during the
interval
If the system time was changed during the interval
If the system was too busy to respond to a poll request
for the interval.