Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-178 Issue 4 May 2002
continuous Display updates as new
messages enter the trace
buffer (FIFO). This option is
most useful in conjunction
with “auto-page.” The
command terminates only
when canceled by the user.
LIFO Newest message displayed
first.
FIFO Messages displayed in the
order received.
[ auto-page ] The screen will
automatically page when
full. Used in combination
with continuous (above),
provides a way to “watch”
as messages arrive.
print
schedule
Report sent to printer.
Command is validated and
then a scheduling form
displays to schedule
execution of the command.
The command is then
placed in the command
queue and is executed at
the specified time. The
information displayed by
the command is sent to the
system printer instead of
the screen.
1
Examples:
list mst continuous
list mst continuous
auto-page
list mst LIFO
list mst from 222 count 7
1 Refer to the Report Scheduler and System Printer feature specification for more details.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions