status data-module
Issue 4 May 2002
8-359555-233-123
Output
For the following output example, the command that was entered is status
data-module 301".
Field descriptions
Data Ext/Sta Ext
for Stn DM
The data module extension number. The DTDM is an
exception: the connected station extension is shown.
Port/Channel
Number
The port location of the data module
(cabinet-carrier-slot-circuit). If the data module specified is a
data channel, the channel number is shown instead.
Service State
This entry displays the status of the data module; valid states
are:
In-service/idle
The data module is present but not in use.
In-service/active
The data module is present and is in use.
Out-of-service
The data module has been removed from service
Disconnected
The data module no longer appears to be present
CF Destination Ext
This entry displays the call forwarding destination, if any, of
the station.
Maintenance Busy?
Whether maintenance is testing the object, yes or no.
Connected Ports
Port locations to which the data module is connected
(cabinet-carrier-slot-circuit).
status data-module 301
DATA-MODULE STATUS
Data Ext/Stn Ext for Stn DM: 301 Service State: out-of-service
Port/Channel Number: 01C1103 Maintenance Busy? no
CF Destination Ext:
Connected Ports: