Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-398 Issue 4 May 2002
maint/idle
SPE in maintenance mode, but no current maintenance
activity. The active SPE can be either active or selected.
maint/entering
SPE currently restarting the switch software on this SPE.
After the switch software on this SPE finishes its
initialization, the standby SPE is available to perform
maintenance functions.
maint/testing
SPE in maintenance mode executing a test command.
maint/
not-refreshed
SPE in maintenance mode executing a destructive
background maintenance test that has temporarily left
the standby memory not refreshed. After the current test
finishes, background maintenance refreshes the
standby SPE.
maint/not-tested
SPE in maintenance mode because previously the
active SPE had been selected with the SPE select
switches. Since the active SPE was not selected, the
standby has not been tested to ensure the standby can
enter standby mode. Once the standby is tested
successfully, the standby returns to standby mode.
maint/list-config
SPE in maintenance mode and currently executing a list
configuration command.
maint/save~trans
SPE in maintenance mode and is currently executing a
save translation command.
maint/
save~announce
SPE in maintenance mode and currently executing a
save announcement command.
maint/status
SPE in maintenance mode and currently executing a
status card-mem command.
maint/patching
SPE in maintenance mode and currently applying a
software patch to the standby SPE memory.
maint/periodic
SPE in maintenance mode and currently performing
periodic background maintenance (performed every two
hours if some component of the standby SPE is
alarmed).
maint/scheduled
SPE in maintenance mode and currently performing
daily scheduled background maintenance.
maint/analysis
SPE in maintenance mode and currently performing
background maintenance testing in response to a
reported trouble by some component in the active or
standby SPE complex that relates to the standby SPE.
maint/upgrade
SPE in maintenance mode and currently performing a
software upgrade.
Down Modes
2
down/bad_upgrade
SPE in down mode (software upgrade attempt failed).
The standby SPE remains in down mode until a
successful software upgrade is performed.