test data-module
Issue 4 May 2002
8-429555-233-123
Output
The following example shows the output from test data-module 300 The
responses display on a test-by-test basis with one line of data for each test result.
Field Definitions
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Test No
The test being executed
Result
Test result: Pass, Fail, Abort, No Board
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test data-module 300
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1103 PDMODULE 17 PASS
Command successfully completed