Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-474 Issue 4 May 2002
Output
The following output example is for the test pri-endpoint 22501 command and
assumes that the PRI endpoint ports for extension 22501 are in cabinet 1, carrier
B, slot 20, circuits 1 to 3. The responses display on a port-by-port and test-by-test
basis with one line of data for each test result.
Field descriptions
Port
The port address (cabinet-carrier-slot-circuit) of the
maintenance object that is being tested.
Maintenance
Name
The maintenance object name for the PRI endpoint port is
PE-BCHL.
Alt. Name
The specified extension number of the PRI endpoint.
Test No
The actual test being executed.
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the list of codes by test number for each MO.
test pri-endpoint 22501 short page 1 of 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B2001 PE-BCHL 22501 36 PASS
01B2001 PE-BCHL 22501 255 PASS
01B2001 PE-BCHL 22501 256 PASS
01B2001 PE-BCHL 22501 257 PASS
01B2002 PE-BCHL 22501 36 PASS
01B2002 PE-BCHL 22501 255 PASS
01B2002 PE-BCHL 22501 256 PASS
01B2002 PE-BCHL 22501 257 PASS
01B2003 PE-BCHL 22501 36 PASS
01B2003 PE-BCHL 22501 255 PASS
01B2003 PE-BCHL 22501 256 PASS
01B2003 PE-BCHL 22501 257 PASS
Command Successfully Completed