Output
The following screen is an example of the output from the test station 81902
short command with the assumptions that port in cabinet 1, carrier c, slot 7, circuit
1 is an analog port and extension 81902 is connected to that port. The responses
display on a test-by-test basis with one line of data for each test result.
Field descriptions
Port
The port address: cabinet-carrier-slot-circuit
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
Alternate means of identifying the maintenance object. This
field contains the extension when the object is a station.
Test No
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the list of codes by test number for each MO.
test station 81902 short
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C0701 ANL-LINE 35 PASS
01C0701 ANL-LINE 48 PASS
01C0701 ANL-LINE 36 PASS