Maintenance Object Repair Procedures
555-233-123
10-4 Issue 4 May 2002
Figure 10-1. Small Cabinet Environment Components (AC-POWER)
Error Log Entries and Test to Clear Values
Refer to the appropriate test description and follow the recommended procedures.
Table 10-1. AC Power Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence.
0 Any Any Any test environment P sh r 1
513 Any AC Power Query
Test (#78)
WARNING OFF test environment P sh r 1
FILTER
CARRIER A
CARRIER B
A
I
R
F
L
O
W
S4
631
S4
631
RING
GENERATOR
S3
FRONT VIEW
A
H
D
1
DA
BATTERY &
BATTERY
CHARGER
AC
DIST.
DA
AC
POWER
ISTRIBUTION
UNIT
F3
631
DB
631
DB
FUSE LOCATIONS FUSE LOCATIONS
PACK IS IN SAME CARRIER
FRONT OF CABINET.
ARE NOT VISIBLE FROM
ON BACK OF CABINET AND
THE 3 FANS ARE ACTUALLY
AC
F6
NOTE: THE 631AR AND
631BR MAY BE USED AS
THE CARRIER POWER UNIT
PROVIDED A TN736 OR
TN752 POWER UNIT CIRCUIT
F3
20A
FUSE F7 IS
FOR CONVENIENCE
OUTLETS
BACK OF POWER DISTRIBUTION UNIT
20A
F6
F7
15A
F8
2A
FRONT OF POWER DISTRIBUTION UNIT
CONVENIENCE OUTLET CONVENIENCE OUTLET

Table of Contents