Maintenance Object Repair Procedures
555-233-123
10-30 Issue 4 May 2002
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present, or some tone detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors in the Error Log.
2. Resolve any “TONE-PT” errors in the Error Log.
1004 ABORT The port was put in use during the test. The test has been
aborted.
1. Use the display port PCSSpp command to determine
the voice port extension of the port.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before testing.
3. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
1020 ABORT Test disabled via background testing.
1. Use the status station command to determine when the
voice port is available for testing.
2. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
2
FAIL The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections. Failure
code 1 indicates that the Crosstalk test failed on the primary
channel. Failure code 2 indicates that the Crosstalk test failed
on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of
this section).
PASS The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat
this test up to a maximum of 10 times to make sure it
continues to pass.
2. If complaints still exist, examine the connections.
Table 10-11. TEST #9 NPE Crosstalk Test — Continued
Error
Code
Te s t
Result Description/Recommendation