ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 4 May 2002
10-37 555-233-123
Table 10-14. TEST #6 NPE Crosstalk Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources for this
test. Try (a).
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1001 ABORT Could not allocate the necessary system resources to run this
test. Try (a).
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS Maintenance documentation to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, retry the command at 1-minute intervals a
maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page