Maintenance Object Repair Procedures
555-233-123
10-64 Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port PCSSpp command, and follow the procedure
for the results of Test #48.
40960indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
40977indicates that no terminal equipment was connected when
ringing was attempted. Run the short Test via the test port PCSSpp
command, and follow the procedure for the results of Test #48.
Table 10-24. 16-Port Neon Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40960
40977
none
15 (b) Any Audits and Updates
Test (#36)
18 0 busyout station
<extension>
WRN ON release station
<extension>
130 (c) None WRN ON test port PCSSpp sh
257 (d) 40973 none
513 (e) Station Present Test
(#48)
WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test
(#35)
MIN/WRN
2
2 Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON test port PCSSpp sh r 2
1025 Loop Around Test
(#161)
MIN/WRN
2
ON test port PCSSpp l r 2
1281 Conference Test
(#7)
MIN/WRN
2
ON test port PCSSpp l r 2
1537 NPE Crosstalk Test
(#6)
MIN/WRN
2
ON test port PCSSpp l r 2