ANL-16-L (16-Port Neon Analog Line)
Issue 4 May 2002
10-79 555-233-123
1008 ABORT Could not allocate a ringing circuit. Either all the ringing
circuits are in use or the ringing generator is defective or it is
not wired correctly.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, look for RING-GEN errors in
the Error Log. If an ABORT 1008 occurs for this test on
other circuit packs as well, then the ringing generator may
be defective or is not wired correctly (see errors for
RING-GEN). If it doesn’t occur on other ports, then all
four ring phases are in use.
1018 ABORT The test has been disabled via administration. The default for
the 'Test' field on the 'Station' form is 'y'; thus, you may want
to determine why this field has been set to 'n' on this station
(this may be due to the brief ringing disturbance that this test
may cause).
1. To enable the test for the particular analog station being
tested, enter change station extension and set the
‘Test ?’ field on the station from 'n' to 'y.'
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-29. TEST #48 Station Present Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page