ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon
Analog Line)
Issue 4 May 2002
10-95 555-233-123
1018 ABORT Test disabled via administration. The default for the ’Test’ field on
the ’Station’ form is ’y’; thus, you may want to determine why this
field has been set to ’n’ on this station (this may be due to the
ringing application test 48, which can be customer or terminal
disturbing).
1. To enable the test for a particular station, enter change
station extension and set the ‘Tes t?’ field on the ‘Station
Form’ to ‘y.’
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not available.
Either a system allocation to get information about the port or to
put the port into a service state failed or the attempt to put the port
in connection with a tone source failed (this could be a tone-clock
problem). The tone-clock and tone detectors could be having a
communication problem, for example, the companding modes
could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-33. TEST #35 Battery Feed Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page