AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-127 555-233-123
1008 ABORT A ringing circuit could not be allocated. Either all of the ringing
circuits are in use, the ringing generator is defective, or it is
not wired correctly.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, look for RING-GEN errors in
the Error Log.
3. If ABORT 1008 occurs for this test on other circuit packs
as well, the ringing generator may be defective or is not
wired correctly (see RING-GEN).
4. If an ABORT 1008 does not occur on other ports, then all
four ring phases are in use.
1018 ABORT Administration has disabled the test. The default for the
Test? field on the station form is y. Determine why this field
has been set to n on this station (this may be due to the
ringing application Test 48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested,
enter change station extension.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.