Maintenance Object Repair Procedures
555-233-123
10-130 Issue 4 May 2002
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine
the station extension.
2. Use the status station extension command to determine
the service state of the port.
3. If the port is in use, wait until the port is idle before testing.
Retry the command at 1-minute intervals no more than 5
times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test
is not applicable for this type of analog port. This error can be
ignored.
1018 ABORT Administration has disabled the test. The default for the Test?
field on the station form is y. Determine why this field has been
set to n on this station (this may be due to the ringing
application Test 48, which can be disturbing to customer or
terminal equipment).
1. To enable the test for a particular station being tested,
enter change station extension.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
Table 10-43. TEST #161 Looparound Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page