ANN-BD (Announcement Circuit Pack)
Issue 4 May 2002
10-147 555-233-123
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to the TTR-LEV (TTR Level) Maintenance
documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to the TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
1007 ABORT The Announcement circuit pack thinks that Port 1 or Port 9 is
busy.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, follow the Announcement
Port maintenance procedures for Ports 1 and 9.
3. If the Announcement Ports pass all their tests, escalate
the problem.
Table 10-48. TEST #210 140AY Loop Around Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page