ASAI-PT
Issue 4 May 2002
10-183 555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI
circuit pack detects that Level 1 has been deactivated on the port. The aux
data field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the Packet Bus,
thus affecting the conveyance of signalling information over D-channel.
This error occurs when the Packet Bus transmit FIFO buffer overflows.
This condition probably indicates a hardware problem as well. The
ASAI-PORT alarm level is MAJOR with aux data 0. Use troubleshooting
procedures for both on-board hardware problems and potential off-board
Packet Bus problems.
Table 10-59. ASAI-PT Port Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm Level
ASAI-PORT
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) (a) Level 1 Status
Inquiry (#621)
MAJ
2
2 Major and Minor alarms may be downgraded to warning alarms based on the value used in the set
options command.
OFF test port PCSSpp sh r 2
513 (b) 0 none (b) ON
1537 (c) 46210 CRC Error
Counter (#623)
MAJ
2
OFF
3841 (d) 46208 None
3844 (e) 46223 None
3845 (f) None
3846 (g) TEI None
Continued on next page
Blank This indicates that the Level 1 Status Inquiry failed.
32773 This is a message from the ASAI-Line circuit pack indicating
Level 1 has been deactivated.