EasyManua.ls Logo

Avaya Definity SI - Page 982

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-196 Issue 4 May 2002
Table 10-66. ATM-BCH alarms by service state
Service state Alarm
1
1 ATM-BCH alarms; alarms against other maintenance objects may also be present.
Possible cause Possible solution
Out-of-Service/NE
Warning Trunk busied out Release the port (release trunk
grp#/mbr#).
Minor NPE Crosstalk Test
(#6) failed
Replace ATM circuit pack.
None ATM circuit pack lost
signal or there is a
circuit pack problem.
Install circuit pack or cable. Check
circuit pack using procedures in
ATM-BCH. Check far-end switch
status.
Out-of-Service/FE
Warning Unadministered far-end Administer the corresponding trunk
on the far-end switch.
Warning Far-end busied out Check the status of the far-end
switch.
Pending/In-Service
Pending/Maint
None Maintenance message
timed out waiting for
reply
Wait 2 minutes after the pending
state clears, and check the service
state.
Maint/NE
None ISDN test call in
progress (test trunk
long)
Wait for the test to finish and recheck.
None System link busied out Check link status. Run release link
link#.
Maint/FE
Warning Signaling channel down
for over 90 sec.
See ATM-SGRP
or ATM-DCH.
Warning Repeated lack of
response to messages
sent to the far end
Wait. Maintenance software resends
messages periodically. Or run test
trunk grp#/mb# or test
signaling-grp grp#.
Warning The far-end trunk is
being tested.
Check status of the far-end switch.
Wait for testing to finish.
In-Service None Normal operating state
Continued on next page