EasyManua.ls Logo

Avaya Definity SI - Page 986

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-200 Issue 4 May 2002
Signaling Link State Audit Test (#255)
This non-destructive test checks the status of the TN230x ATM-CES Interface
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important
elements to the health of the ATM-BCH trunk.
Table 10-68. System Technician-Demanded Tests: ATM-BCH
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Destructive or
Non-destructive
Signaling Link State Check Test (#255) X X ND
Service State Audit Test (#256) X X ND
Call State Audit Test (#257) X X ND
ISDN Test Call Test (#258) X ND
Continued on next page
Table 10-69. TEST #255 Signaling Link State Audit Test
Error
Code
Te s t
Result Description/Recommendation
None ABORT Internal system error
0 ABORT
1114 ABORT Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018 ABORT Maintenance disabled
1. Enable maintenance. Enter y in the Maintenance Tests?
field on page 2 of the change trunk-group form.
4 FAIL Signaling channel problem
1. Look for errors or alarms against the ‘‘ATM-SGRP (ATM
Signaling Group)’’ and ‘‘ATM-DCH (ATM D-Channel Port)’’
maintenance objects.
8 FAIL TN230x circuit pack failed
1. See the ‘‘ATM-INTF (TN2305/6)’’ maintenance object.
PASS Signaling link OK.
Continued on next page