Maintenance Object Repair Procedures
555-233-123
10-212 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 23: ATM Expansion Interface circuit pack is administered
through a change circuit-pack command, but has not been inserted into
the system. Insert the circuit pack.
b. Error Type 125: A wrong circuit pack is located in the slot where this circuit
pack is logically administered. To resolve this problem, either remove the
wrong circuit pack or insert the logically administered circuit pack.
c. Error Type 217: The ATM circuit pack is physically present but has not
been given a personality. Remove the circuit pack or administer it using the
add atm pnc command or add atm trunk command.
System Technician-Demanded Tests: Descriptions
and Error Codes
Failure of this test is not logged in the Error Log.
Table 10-77. ATM-INTF Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
23(a) 0 None WAR OFF
125(b) None MIN ON
217(c) 0 None WAR OFF
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive, ND = Non-destructive
Control Channel Loop Around Test (#52) X X N