Enter/Exit Programming Mode
354
Magellan™ 9800i Scanner
MSI Length 1
If MSI Length Control is set to Fixed-Length decoding, this feature specifies MSI first fixed
length. If MSI Length Control is set to Variable-Length decoding, this feature specifies the
minimum label length.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the barcode, Set MSI Length 1 below. You’ll need to cover any unused barcodes on
this and the facing page to ensure that the scanner reads only the barcode you intend to
scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
label length. The selectable range for this option is 4
to 16. Pad all single digit numbers
with a leading zero to yield a two-digit entry (04-16).
4. Complete the programming sequence by scanning
the ENTER/EXIT Programming
Mode bar code.
Set MSI Length 1
DEFAULT
Default setting for this feature = 04