Enter/Exit Programming Mode
128
Magellan™ 9800i Scanner
Scale Zero Button and Scale Indicator LED
Here are the configurable options for the Scale Zero Button and Scale Indicator LED:
Scale Zero Button and Scale Indicator LED active
Scale Indicator LED active
Scale Zero Button active
Scale Zero Button and Scale Indicator LED disconnected
NOTE
The options on this page are for adaptive scale bonnet integration only.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the desired mode bar code from those provided below You’ll need to cover any
unused bar cod
es on facing pages to ensure that the scanner reads only the bar code you
intend to scan.
3. Complete the programming sequence by scanning the
Enter/Exit Programming Mode bar
code.
06F100(CR)
Scale Zero Button and Scale Indicator LED = Scale Zero
Button and Scale Indicator LED active
06F101(CR)
Scale Zero Button and Scale Indicator LED = Scale Indica-
tor LED active
06F102(CR)
Scale Zero Button and Scale Indicator LED =
Scale Zero Button active
06F103(CR)
Scale Zero Button and Scale Indicator LED = Scale Zero
Button and Scale Indicator LED disconnected