EasyManua.ls Logo

Datalogic Magellan 9800i - Beep after Weigh

Datalogic Magellan 9800i
452 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
190
Magellan™ 9800i Scanner
RS-232 Beep After Weigh
Enables/disables the ability of the scanner to beep after weight data is transmitted to the host.
Scale interfaces that support this item are: RS-232 ICL, RS-232 SASI, and RS-232 Single
Cable.
To enable/disable the Beep After Weigh feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes
on this and
the facing page to ensure that the scanner reads only the bar code you intend
to scan.
3. Complete the programming sequence by scanning the
Enter/Exit Programming Mode bar
code.
DEFAULT
041C00(CR)
RS-232 Beep After Weigh = Disable
041C01(CR)
RS-232 Beep After Weigh = Enable

Table of Contents

Other manuals for Datalogic Magellan 9800i