394
Magellan™ 9800i Scanner
ScaleSentry / Scale Service Button
The ScaleSentry / Scale Service Button (item #3 in Figure 58) is used for multiple functions as
listed in Table 18.
Table 18. ScaleSentry / Scale Service Button Functions
PRESS
DURATION
FUNCTION COMMENT
Momentary Override
If a ScaleSentry event is occurring, this will override the scale sentry
ev
ent. If no ScaleSentry event is occurring, this will activate the man-
ual tare function of the scale.
4 Seconds
Scale Diagnostics
Mo
de
a
a.
Diagnostics Mode is meant for use by trained systems support personnel. Users should
not need to initiate this function under normal circumstances.
This mode allows system support personnel to troubleshoot problems
with the scale. Momentarily press the Scale Zero Button or cycle power
to exit Scale Diagnostics Mode. See the topic, Scale Error Reporting
in the Problem Isolation section for more details.
8 Seconds Resets Scanner Only system support personnel should perform a reset.
Momentary while
in S
cale
Diagnostics Mode
Resets Scanner
A scanner reset can also be initiated by a momentary press of this but-
ton while in Scale Diagnostics Mode.
DECOUPLED MODE
Deactivation
Indicated
Deactivation (Tri-color) LED
flashes Red
.
EAS Beep OFF
An EAS tag has been
suc
cessfully deacti-
vated.
HYBRID MODE
Deactivation
Indicated
Deactivation (Tri-color) LED
f
lashes Red, then Orange, then
returns to Green.
High frequency beep
An EAS tag has been
successfully deacti-
vated.
a.
Additionally, the FRU LED (Health & Status Indicator located in the bottom of the
optic cavity — visible through the horizontal scan window) blinks the number ‘9’. If
EAS deactivation fails to initiate, a low, error tone will be sounded, and the FRU LED
will display the error code ‘9’ steadily (without flashing).
b.
Ticking sound will stop upon one of the following: 1) Manual EAS Deactivation Push
Button is pressed and released again, 2) EAS timer runs out, or 3) Following a suc-
cessful EAS tag deactivation.
Table 17. EAS Indications