Enter/Exit Programming Mode
156
Magellan™ 9800i Scanner
EAS Deactivation Duration — Coupled
Specifies the amount of time EAS deactivation is operative once the function has been
initiated following a bar code read.
NOTE
This setting pertains only to units configured for EAS Coupled Mode. Refer-
ence the
EAS Mode
description for more information about Coupled and
Decoupled EAS operation.
To set the EAS Deactivation Duration — Coupled:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code, Set EAS Deactivation Duration — Coupled below. You’ll need
to cover any unused bar codes on this and the facing page
to ensure that the scanner
reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Keypad in Appendix C that represent the desired
duration. The selectable range is 1-255, which is the
duration in 10-millisecond incre-
ments. Pad all single and double digit numbers with leading zeroes t
o yield a three-
digit entry (001-255).
Examples:
005 = 50ms
040 = 400ms
250 = 2,500ms (2.5 seconds)
4. The scanner will automatically exit Programming Mode when the appropriate amount
o
f digits have been scanned.
Set EAS Deactivation Duration — Coupled
DEFAULT
Default setting for this feature is:
040 = 400ms