Variables and Commands CDHD
100 VarCom Reference Manual
FOLD
Definition Drive Foldback Status
Type Variable (R)
Description Indicates whether the drive foldback limit (IFOLD) has
dropped below the application’s current limits (ILIM).
Syntax FOLD
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = Foldback limit above ILIM
1 = Foldback limit below ILIM
Default value Not Applicable
Unit Not Applicable
Non-volatile No
See also DICONT
IFOLD
IFOLDFTHRESH
IFOLDWTHRESH
ILIM
CANopen 2051h, sub-index 0