CDHD Variables and Commands
VarCom Reference Manual 95
FILTHZ2
Definition Velocity Loop Output Filter Parameter 2
Type Variable (R/W)
Description Velocity loop output filter second parameter.
A multi-function parameter for setting the output filter of the
velocity controller. FILTMODE defines its functionality.
Syntax Read: FILTHZ2
Write: FILTHZ2 <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 1 to 10000
Default value 200
Unit Hz
Non-volatile Yes
See also FILTHZ1
FILTMODE
CANopen 204Fh, sub-index 0