Variables and Commands CDHD
94 VarCom Reference Manual
FILTHZ1
Definition Velocity Loop Output Filter Parameter 1
Type Variable (R/W)
Description Velocity loop output filter first parameter.
A multi-function parameter for setting the output filter of the
velocity controller. FILTMODE defines its functionality.
Syntax Read: FILTHZ1
Write: FILTHZ1 <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 1 to 10000
Default value 200
Unit Hz
Non-volatile Yes
See also FILTHZ2
FILTMODE
CANopen 204Eh, sub-index 0