CDHD Variables and Commands
VarCom Reference Manual 321
PHASEFINDGAIN
Definition Phase Find Gain
Type Variable (R/W)
Description Adjusts the gain of the phase finding mechanism.
Syntax Read: PHASEFINDGAIN
Write: PHASEFINDGAIN <value>
Firmware 1.0.6
Drive status Disabled
Range 0 to 10
Default value 1
Unit Not applcable
Non-volatile Yes
See also PHASEFIND
PHASEFINDMODE
CANopen 20A6h, sub-index 0