EasyManua.ls Logo

Servotronix CDHD - Kcp

Servotronix CDHD
416 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variables and Commands CDHD
184 VarCom Reference Manual
KCP
Definition Current Kp Gain
Type Variable (R/W)
Description Gets/sets the current controller proportional (Kp) gain.
When the value of KCP is changed, CONFIG is required.
Syntax Read: KCP
Write: KCP <value>
Firmware 1.0.6
Drive status Disabled
Range 0 to 100
Default value 1.000
Unit Not Applicable
Non-volatile Yes
See also KCBEMF
KCFF
KCI
CANopen 2007h, sub-index 0