Variables and Commands CDHD
352 VarCom Reference Manual
RESBW
Definition Resolver Conversion Bandwidth
Type Variable (R/W)
Description Get/sets the resolver conversion bandwidth. High bandwidth
produces better dynamic tracking and less phase lag in high
frequencies. Lower bandwidth results in better noise
reduction.
Resolvers typically enable slower dynamic tracking than
encoders. RESBW sets the most balanced value according to
specific application requirements.
Syntax Read: RESBW
Write: RESBW <value>
Firmware 1.0.6
Drive status Disabled
Range 200 to 800
Default value 300
Unit Hz
Non-volatile Yes
See also FEEDBACKTYPE
SININIT
VELFILTMODE
CANopen 20BCh, sub-index 0