CDHD Variables and Commands
VarCom Reference Manual 149
IFOLDFTHRESH
Definition Drive Foldback Fault Threshold
Type Variable (R/W)
Description Gets/sets the current threshold level for declaring a fault due
to foldback.
The drive foldback threshold fault is declared when IFOLD
drops below IFOLDFTHRESH.
Syntax Read: IFOLDFTHRESH
Write: IFOLDFTHRESH <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 to 300
Default value DICONT
Unit A
Non-volatile Yes
See also DICONT
FOLD
IFOLD
IFOLDWTHRESH
ILIM
CANopen 206Ah, sub-index 0