Variables and Commands CDHD
154 VarCom Reference Manual
IMAX
Definition Drive Current Limit
Type Variable (R)
Description Displays the maximum current limit for a drive and motor
combination.
Syntax IMAX
Firmware 1.0.6
Drive status Enabled | Disabled
Range Not Applicable
Default value Not Applicable
Unit A (peak)
Non-volatile No
See also DIPEAK
I
ILIM
MIPEAK
CANopen 6073h, sub-index 0